Ports And Connections - Pratissoli LK Serie Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para LK Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
Do not release used oil into the environment under any circumstances.
8

PORTS AND CONNECTIONS

The LK series pumps are equipped with (see Fig. 4 and Fig. 5):
2 "IN" inlet ports:
G2" (on LK36, LK40, LK45 versions)
Ø80 mm (on LK50, LK55, LK60 versions).
Line connection to any of the two ports is indifferent for
proper pump functioning. The unused ports must be
hermetically closed.
2 "OUT" outlet ports:
G1" (on LK36, LK40, LK45 versions)
Ø36 mm (on LK50, LK55, LK60 versions).
1 "DRAIN" port: with G1/2" orifice obtained in the lower cover
to monitor any leakage of water due to wear on the pressure
seals. If there are any leaks, refer to the Repair manual.
This orifice must always be kept open.
Ambient temp. (°C)
31
Fig. 4
Fig. 5

Publicidad

Tabla de contenido
loading

Tabla de contenido