Madas M16/RM N.A. EEX Manual Del Usuario página 14

Electroválvula con rearme manual normalmente abierta para gas
Ocultar thumbs Ver también para M16/RM N.A. EEX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9.0 - RATING PLATE DATA
The plate data (see examples provided here) includes the following:
• Manufacturer's name/logo and address (possible distributor name/logo)
• Mod.:
= name/model of the device followed by the diameter size
• P. max
= Maximum pressure at which product operation is guaranteed
• PS
= Allowable maximum pressure
• IP....
= Protection rating
• 220-240V.... = Power supply voltage, frequency (if Vac), followed by electrical absorption
• TS
= Temperature range within which product operation is guaranteed
= In compliance with PED Dir. followed by Notified Body No.
= Conformità Dir. ATEX seguita dal modo di protezione
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1745
= Lot issued in year 2017 in the 45th week
• 25407
= progressive job order number for the indicated year
• 00001
= progressive number referred to the quantity of the lot
= Disposal in accordance with WEEE directive 2012/19/EU
Coil protection mode
II
product group
2
product category
Gas: II 2G Ex mb IIC T... Gb X
G
explosive atmosphere with gas or vapours
Ex
suitable for explosive atmosphere
mb
encapsulated for zone 1
IIC
explosion group
T...
temperature class (T4 < 135 °C) - (T5 < 100 °C) - (T6 < 85 °C)
Gb
Product Level (EPL) - equipment for use in explosive atmospheres due to the presence of gas, with an "high" level
of protection, which is not a source of ignition in normal operation or during expected malfunctions
X
particular conditions of use (*)
Dust: II 2D Ex mb tb IIIC T...°C Db X
D
explosive atmosphere with dust
Ex
suitable for explosive atmosphere
mb
encapsulated for zone 21
tb
protection by enclosure for zone 21
IIIC
explosion group
T...
temperature class expressed in °C
Db
Product Level (EPL) - equipment for use in explosive atmospheres due to the presence of gas, with an "high" level
of protection, which is not a source of ignition in normal operation or during expected malfunctions
X
particular conditions of use (*)
* see paragraph 3.2 - "Special conditions for safe use"
M16/RM N.A. EEX
Mod.: M16/RM N.A. DN 50 EEX
IP65 - 220-240 V/50-60 Hz 7,7-9,4 VA (-20...+50) °C
year: 2017
14
Madas Technical Manual - 3|3.3b - REV. 0 of 10
Via Moratello, 5/7 - 37045
Legnago (VR) - Italy
www.madas.it
P. max=PS=6 bar
II 3G
0497
II 3D
Lot:U1745
25407/00001
Sep 2019