06.2005
Analog input (differential input)
•
Input range
Voltage
Current
•
Input resistance
Voltage
Current
•
Hardware smoothing
•
Resolution
Analog input (single-ended),
can also be used as digital input
•
Input range
•
Input resistance
•
Hardware smoothing
•
Resolution
•
As digital input:
Switching threshold HIGH
Analog output
Current or voltage signal
•
Voltage range
•
Hardware smoothing
•
Resolution
5.3
Installation
NOTE
Siemens AG
6SE7087-6NX84-0FF5
SIMOVERT MASTERDRIVES
AI1P, AI1N
± 10.0 V (± 1 V reserve)
± 20 mA (± 2 mA reserve)
40 kΩ to ground
50 Ω to ground
220 µs
13 bit + sign
AI2, AI3 AIM
± 10,0 V (± 1 V Reserve)
40 kΩ to ground
220 µs
13 bit + sign
> 8 V
AO1, AO2, AOM
± 10.0 V / ± 5 mA
10 µs
11 bit + sign
Table 5-2
Technical data of EB1
If the inverters/converters are ordered with optional functions, the
optional boards are already installed in the units when they are
delivered.
It is possible to retrofit optional boards and this can be carried out by
the user.
For this purpose, there are either two or up to six slots on the basic unit
depending on the type of construction for mounting the optional boards.
An exact description of installation is included with the relevant basic
unit. As the unit has to be removed and opened in order to install
optional boards, attention must be paid to the ESD measures. Please
refer to the operating instructions of the basic unit in this regard.
Generally, you can install the EB1 optional board in every slot.
However, please observe that an encoder board for MASTERDRIVES
Motion Control always requires slot C.
A maximum of two EB1s can be installed per unit.
Option boards
EB1 – Expansion Board 1
5-3