Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SBM – Sensor Board Encoder / Multiturn (only for MASTERDRIVES Motion Control)
9.3

Installation

NOTE
9-4
If the inverters/converters are ordered with optional functions, the
optional boards are already installed in the units when they are
delivered.
It is possible to retrofit optional boards and this can be carried out by
the user.
For this purpose, there are either three or up to six slots on the basic
unit depending on the type of construction for mounting the optional
boards.
An exact description of installation is included with the relevant basic
unit. As the unit has to be removed and opened in order to install
optional boards, attention must be paid to the ESD measures. Please
refer to the operating instructions of the basic unit in this regard.
Generally, you can install the SBM optional board in every slot.
However, bear in mind that a sensor board always requires slot C.
6SE7087-6NX84-0FF5
Option boards
SIMOVERT MASTERDRIVES
06.2005
Siemens AG

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cbp2CbcSlbEb1Eb2Sbp ... Mostrar todo

Tabla de contenido