Electrical Connection - Festo HSP-AE-IO Serie Manual De Instrucciones

Ocultar thumbs Ver también para HSP-AE-IO Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Warning
Use only power units which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN
EN 60204−1. Observe also the general requirements for
PELV power circuits as per IEC/DIN EN 60204−1.
Use closed−circuit power units with a high output
S
reserve (40 %), in order to enable a fast increase in
current:
Use only the specified cables (accessories) and seal
S
unused connections with protective caps.

Electrical connection

Supply voltage
Rated motor current
Peak motor current
Supply cable
Control cable
Programming cable
The tolerance must also be observed directly at the power
*)
connection.
22
HSP−12/16−AE: peak current 6 A at 24 V DC
HSP−25−AE:
HSP−12/16−AE
24 V DC ±10 %
2 A ±20 %
3.8 A ±20 %
Type KPWR−MC−1−SUB−9HC−...
Type KES−MC−1−SUB−9HC−...
Type KDI−MC−M8−SUB−9−...
peak current 10 A at 24 V DC
*)
Festo P.BE−K−HSP−AE−IO 0510NH English
HSP−25−AE
5.1 A ±20 %
7 A ±20 %

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pbek-hsp-ae serie

Tabla de contenido