RIB VERTIGO Serie Manual Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

VERTIGO conforms to standards EN12978 and EN13849-2 (2013) when used with a RIB electronic
control panel it is a PL "c" Category 2 protection device for protecting persons/things from
collisions caused by mechanical moving parts such as automatic gates or doors.
The obstacle is detected for the whole distance between the infrared transmitter and receiver
which constitute the VERTIGO product.
When using RIB electronic control panels you can run auto-tests on the system.
With RIB actuators, RIB electronic control panels having the auto-test function and RIB safety
devices you can create an installation that conforms to the European Directives and Norms in
force.
After completing the system, you must make sure it conforms to standard EN13241-2016.
RIB shall not be liable for any damages caused by improper, incorrect or unreasonable use of
the product.
VERTIGO photocells cannot be used on devices excluded by the application of the EN12978,
such as:
- Protection devices for the installation on doors used for a different purpose to those ones
used for pedestrian or veheicle access, covered by the norm which principal intent is that of
allowing a safe access to industrial, commercial, public and commercial sites. Some examples
of excluded accesses can be: sluice gates, dams, lift doors, vehicles' doors, doors used mainly
to restrain animals, theatre curtains, railways barriers, barriers used only for vehicles.
- Devices used only fo the standard control and for the stopping, including the emergency
stopping, of motorized doors.
- Safety systems and safety devices used on machineries different from doors.
Any possible modification of the device, or of the configuration of the same cannot be carried
out without the clear authorization by the manufacturer or, by the local authorized dealer.
The installer of the safety device must make sure that the end user know the following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any obtsacle.
- About the procedures for cleaning so to avoid the dangerous building up of material.
- The possible details for a restart of the system after an emergency or accidental stop caused
by the control system.
Any modification of the project or, of the configuration of the device, without discussing it
first with the manufacturer or with the local autorized dealer can cause dangerous situations.
VERTIGO are produced in wall-type versions:
code ACG8044
code ACG8045
to be fasten to the primary and/or secondary borders (mobile or fixed) made of iron or other
smooth material.
- VERTIGO comes with the infrared ray set as per Fig. 6.
It is possible to direct the infrared ray according to the needs:
APPLICATION
MAX GATE WEIGHT
VERTIGO 8
VERTIGO 10
MAX DISPLACEMENT SPEED
150 kg
13 m/min.
300 kg
10 m/min.
500 kg
13 m/min.
1000 kg
10 m/min.
MOUNTING
VERY IMPORTANT!
Verify that when using a NOT RIB control
panel, this one must be complying with
the reaction time (inversion) requested by
the Norm EN 12453 (requirements of safety
devices used on motorized gates/doors).
PLACE THE RECEIVER OF THE PHOTOCELL ON
THE TOP OF THE COLUMNS OF THE GATE.
THE VERTIGO TRANSMITTER MUST BE
APPLIED TO THE BOTTOM OF THE COLUMNS
OF THE GATE.
13
G
B
RX
TX

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vertigo 8Vertigo 10Acg8044Acg8045

Tabla de contenido