TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nilfi sk-Advance Service
Center immediately for service.
MACHINE WILL NOT START
Possible causes may be:
1
Foot Pedal not in neutral position (ensure pedal is in neutral position)
2
Foot Pedal neutral position is not correctly set (contact your Nilfi sk-Advance service center)
3
Battery is not connected (connect battery)
4
Machine is out of fuel (refuel)
5
Tripped circuit breaker(s) (reset any tripped circuit breakers)
MACHINE WILL NOT MOVE
Possible causes may be:
1
Parking Brake (F) set (release parking brake)
2
Towing Valve in wrong position (set correctly)
3
Tripped circuit breaker(s) (reset any tripped circuit breakers)
MAIN BROOM WILL NOT RUN
Possible causes may be:
1
Debris wrapped around the broom drive (remove debris)
2
Hopper is not completely down (lower hopper completely)
3
Tripped circuit breaker(s) (reset any tripped circuit breakers)
SIDE BROOM WILL NOT RUN
Possible causes may be:
1
Ensure Side Broom OFF switch isn't selected (push switch to turn ON)
2
Debris wrapped around the broom drive (remove debris)
3
Hopper is not completely down (lower hopper completely)
4
Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER WILL NOT RAISE
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER DUMP DOOR WILL NOT OPEN
Possible causes may be:
1
Dump door jammed by debris (remove debris and clean edges of dirt chamber)
2
Tripped circuit breaker(s) (reset any tripped circuit breakers)
SHAKER MOTOR WILL NOT RUN
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
DUST CONTROL SYSTEM (IMPELLER) WILL NOT RUN
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
2
Ensure Dust Control OFF switch isn't selected (push switch to turn ON)