GYS TITANIUM 400 AC/DC Manual De Usuario página 47

Ocultar thumbs Ver también para TITANIUM 400 AC/DC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

COMPATIBLE TORCHES AND TRIGGER BEHAVIOURS
Trigger
L
For the 1 button torch, the button is called «main button».
DB
For the 2 buttons torch, the first button is called «main button» and the second button is called «secondary button».
2T MODE
P
t
t
t
Main button
Main button
T1
T1
Main button
T1
4T MODE
t
t
t
Main button
T1
T2
Main button
T1
T2
Main button
T1
T2
4T MODE log
<0.5s
<0.5s
<0.5s
t
t
t
Main button
Main button
T1
T2
T1
T2
Main button
T1
T2
or
or
or
Secondary button
Secondary button
Secondary button
For this mode it may be convenient to use the dual button torch option or dual button with potentiometer. The «up» command keeps the same func-
tion as the single button or trigger torch. The «down» button can, when pressed, switch to the cold current. The potentiometer of the torch, where
available, can control of the welding current from 50% to 100% of the value displayed. The Up & Down functions allow the adjustment of the lamp
current.
TITANIUM 400 AC/DC
L
Double Button
DB
P
t
t
t
T2
T2
T2
t
t
t
T4
T3
T4
T3
T4
T3
<0.5s
>0.5s
<0.5s
>0.5s
<0.5s
>0.5s
t
t
t
T3
T4
T3
T3
L
DB
Double Button + Potentiometer
P
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary
button works like the main button.
T1 - The main button is pressed, the cycle starts at PreGas and
stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and in welding.
T3 - The main button is pressed, the cycle switches to DownSlope
and stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiome-
ter
=> command « up/welding current » and active potentiometer,
command «low » inactive.
T1 - The main button is pressed, the cycle starts at PreGas and
stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and in welding.
LOG : this mode is used during welding :
- A brief press of the main button (<0.5s), the current switches
from I welding current to I cold and vice versa.
- the secondary button is kept pressed, the welding current swit-
ches from I welding current to I cold
T4
- the secondary button is kept released, the welding current swit-
T4
ched from I cold to I welding current.
T3 – A long press on the main button (>0.5s), the cycle switches to
DownSlope and stops in the I_Stop phase.
T4 - The main button is released, the cycle finishes with PostGas.
EN
Up & Down
UP
Down
47

Publicidad

Tabla de contenido
loading

Tabla de contenido