GYS TITANIUM 400 AC/DC Manual De Usuario página 48

Ocultar thumbs Ver también para TITANIUM 400 AC/DC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

COMMAND TRIGGER CONNECTOR
DB
P
L
Cabling diagram for the SRL18 torch.
Torch double button +
potentiometer
Up
Down
DB
Up & Down torch wiring diagram.
48
TITANIUM 400 AC/DC
1
P
5
torch
2
4
L
DB
torch
2
torch
3
Torch type
Torch double button
1
5
Up & Down
2
4
DB
2
3
Torch type
Up & Down Torch
4
3
5
2
6
1
NC
Electric diagram based on type of torch used.
Torch with trigger
4
3
Switch 1
5
2
6
1
Switch Down
NC
Switch Up
Electrical diagram of the Up & Down torch.
Wire description
Commun
Switch 1 & 2
Switch 1
Switch 2
Commun
Switch Up & Down
Switch Up
Switch Down
EN
DB torch
3
4
L torch
2
2
DB + P
5
torch
1
Wire description
Pin
Common/Earth
2 (green)
Button 1
4 (white)
Button 2
3 (brown)
Common/Potentio-
2 (grey)
meter earth
10 V
1 (yellow)
Cursor
5 (pink)
3
4
Switch 2
2
2
2.2 k
5
2.2 k
1
Pin
2
4
3
5
1
2

Publicidad

Tabla de contenido
loading

Tabla de contenido