POWER SWITCH

• This equipment is supplied with a 32A 3-phase 5-pin socket (3P+N+PE) of the EN 60309-1 type and is powered by a 400V (50-60Hz) 3-phase elec-
trical installation WITH neutral grounded.
The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or
circuit breaker) are compatible with the current needed by the machine. In some countries, it may be necessary to change the plug to allow the use
at maximum settings. The user has to make sure that the plug can be reached.
• The device turns into protection mode if the power supply tension is below or above the 15%. To indicate this default, the screen displays an error
code.
• The power is switched on by rotating the on/off switch to position I (fig 1 - 9), conversely the power is switched off by rotating it to position O.
Attention! Never disconnect the power supply when the welding electrical distribution is in operation.
• Fan: in MMA mode, the fan works continuously. In TIG mode, the fan works only when welding, then stops after cooling.
CONNECTION TO A GENERATOR
This welding power source can operate with generators provided that the auxiliary power meets the following requirements:
- The voltage must be alternative, adjusted as specified and with a peak voltage of less than 700 V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as certain generators can create high voltage peaks that can damage these machines.
USE OF EXTENSION LEADS
All extension cables must have an adequate size and section, relative to the machine's voltage. Use an extension lead that complies with national
safety regulations.

GAS CONNECTION

The TITANIUM 400 AC/DC is equipped with two connections. A cylinder connection (Fig 1 - 12) for the inlet of the welding gas into the station, and
a torch gas connector (Fig 1 - 6) for the outlet of the gas at the end of the torch. We recommend that you use the adapters supplied with your set
to ensure an optimal connection.
GENERAL ORGANIZATION OF THE INTERFACE
Product configuration :
1/ Information: all product information is gathered there (Model, S/N.......)
2/ Process: allows you to choose the welding process: MMA or TIG.
3/ Settings: the advanced product settings are combined (display mode, device name,
language...)
1
4/ Calibration: allows you to start the calibration of the torches and earth clamps to refine
the voltage and current measurements.
5/ Portability: allows to load or download from a USB key the user JOBs as well as the
machine configuration,
6/ Traceability: allows to start the backup of all welding seams as well as its export on USB
key
Process: corresponds to the MMA or TIG welding interface, it gives access:
• Gas purge: by long pressing the process icon
2
• Process parameter: allows process settings,
• At the different setting windows,
• JOB: gives access to the different JOB reminder modes.
Process parameters: corresponds to the process parameter setting window:
• In MMA: allows the adjustment of the sub-process (STD, PLS or AC), the type of elec-
trode, the anti-sticking.....
• In TIG: allows the adjustment of the process (DC, AC or Synergic), the sub-process
3
(STD, PLS or AC), the electrode diameter...
Remote control: configuration of remote controls (TIG mode).
Energy: configuration of the energy mode, developed for welding with energy control
supervised by a DMOS (see next page for more details).
32
TITANIUM 400 AC/DC
Voltage input
Thickness of the extension lead (Length < 45m)
400 V
6 mm²
EN

Publicidad

Tabla de contenido
loading