Greenlee IPM-300 Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation (cont'd)
Using the IPM-300 as a Source
Select the Source mode by pressing the SOURCE/READ button until "SOURCE" appears on the
display.
Using SOURCE Outputs
Outputs are adjustable with the digital pot. All three positions of the switch allow adjustments
of the value. Stored values (HI or LO) are updated by following the procedure below.
SOURCE
HI
SET
LO
Storing Output Values
Output values can be stored into memory where they remain for later use. Values can be
moved from SET into HI or LO. Returning the meter to its defaults replaces the stored values
with its defaults.
STORE/RESET
1.
Press the SOURCE/READ button until "SOURCE" appears on the display.
2.
Flip the toggle switch to HI or LO.
3.
To change the output value, turn the digital pot.
4.
Press the STORE/RESET button to store the value.
5.
To transfer the value in SET to HI or LO, press and hold STORE while moving the switch
to HI or LO.
The display flashes once and the unit beeps once.
6.
Release STORE.
7.
To use a stored value, flip the toggle switch to HI, SET, or LO.
14
All manuals and user guides at all-guides.com

Publicidad

Tabla de contenido
loading

Tabla de contenido