Dalla Corte DC PRO XT Manual Del Usuario página 110

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Alarm
Cause
Level
This alarm is triggered when
timeout
the autofill function fails to bring
the water in the boiler to the
pre-established level within
the time set in the programming
Safety
This alarm is triggered when
level
the water level in the boiler
drops below the safety sensor's
threshold
Grinder
This alarm is triggered when
service
the espresso machine
failure
and the grinder connected
to are unable to communicate
with each other (GCS function)
Cashier
This alarm is triggered when
serial
the coffee machine and the cashier
port
connected to it are unable
failure
to communicate with each other
110 |
Effect
Autofill function is blocked; tap DEL
on the display to cancel the alarm
and restart the autofill
Boiler heating is blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider
Grinder auto-regulation blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider and temporarily
use the continuous dispensing button
All brewing is blocked; tap DEL
on the display to cancel the alarm.
If the alarm repeats, contact an authorized
technical service provider