Maintenance
4.2.3 Put on the facepiece
WARNING
Danger of injury or death!
Putting on the facepiece while the breathing air supply is not
correctly connected and switched on can result in injury or death.
► Correctly connect and turn on the breathing air supply. Put
on in the correct order.
1. Connect the facepiece to the breathing air supply with the
hose.
2. Turn on the breathing air supply.
3. Stretch the sealing cuff of the facepiece with your hands.
4. Put on the facepiece.
5. Use the adjusting wheel to adjust the headband to fit your
head.
6. Adjust the air outlet to the desired position.
7. Pull the sealing cuff under your chin and tighten the strap
until the sealing cuff fits around your neck.
8. Dräger X-plore 8000 helmet with visor:
Close the visor.
9. Dräger X-plore 8000 helmet/hood combination or bump
cap/hood combination:
Insert inner bib into protective clothing. Pull outer bib over
the protective clothing.
4.3

During use

WARNING
Danger of injury or death!
If the breathing air supply fails, a build-up of carbon dioxide
and oxygen deficiency can quickly occur in the facepiece.
Respiratory protection is then no longer provided. There is
danger due to oxygen deficiency, CO
penetration of contaminants from the ambient air!
► Leave the danger zone immediately.
WARNING
Insufficient protection after impact!
If the facepiece absorbs the energy of an impact, it can be
damaged or destroyed.
► Even if damage is not immediately visible, the facepiece
must be replaced after a strong impact or shock and must
not be used any further.
4.4

After use

WARNING
Danger of injury or death!
Danger due to oxygen deficiency, CO
penetration of contaminants from the ambient air!
► Do not turn off the breathing air supply until you have
removed the facepiece.
► Only remove the facepiece when in a place where the
ambient air is no longer contaminated.
1. Clean the facepiece.
2. If necessary, maintain facepiece.
16
poisoning, and
2
poisoning, and
2
5
Maintenance
5.1

Cleaning and disinfecting

NOTICE
Danger of material damage!
Do not use solvents (e.g., acetone, alcohol) or cleaning
agents with abrasive particles for cleaning and disinfecting.
► Only apply the described procedures and use the
specified cleaning agents and disinfectants. Other agents
and procedures, dosages and contact times can damage
the product.
► Coated visors must not be disinfected as the disinfectant
destroys the coating.
► Coated visors must not be cleaned mechanically as this
damages the coating.
► Hoods should not be disinfected as they show damage
after a few disinfection cycles.
For information on suitable cleaning agents and disin-
fectants and their specifications, see document
9100081 at www.draeger.com/IFU .

5.1.1 Manual cleaning

Facepieces where the helmet trim or hood is made of
®
Tychem
cannot be cleaned.
1. Remove hood or helmet trim from the facepiece.
2. X-plore 8000 helmet:
Remove visor shield.
3. Prepare a cleaning solution containing water and a
cleaning agent. Alternatively, you can use lukewarm soapy
water.
4. Clean the components as follows:
● Clean the helmet trim made of Zytec
bump cap in an immersion bath.
Rinse with fresh water and wipe dry.
Allow the comfortable padding and sweatband to dry.
● Clean the visor shield with lukewarm soapy water.
Rinse with fresh water.
Leave to air dry.
5. If you are disinfecting the helmet trim, sweatband, helmet,
or bump cap:
a. Prepare a disinfectant bath of water and a disinfecting
agent.
b. Place the components in the disinfectant bath.
c. Rinse the components thoroughly under running water
and allow to dry.
6. Check all components. Cracked or scratched components
must be replaced.
All parts can be dried in the air or in a drying cabinet
(temperature: max. 60 °C, time: max. 2 h). Keep away
from direct sunlight.
Instructions for use
|
®