8. Attach the brass unions to the cut copper
lines:
A. Slip a brass ferrule (ring) into the large
end of one of the compression nuts. See
Figure 5.
B. Gently thread the nut with the ferrule
onto the union. Be sure the union bot-
toms out against the ferrule. See inset
drawing of Figure 5.
C. Push the copper tubing into the small end
of the compression nut as far as it will go
(about 1/2").
D. Tighten the unions with a wrench.
Small
end of
Compression
Nut
Nut &Ferrule
Union
Copper
Water
NOTE:
Line
The ferrule butts
up against the union.
Figure 5
Tubing Assembly
Brass
Small end
Compression
Nut
Poly-tubing
Plastic
Compression
Sleeve
Large
end
Small
end
Figure 6
Complete Tubing Assembly
9. Cut the poly tubing into two pieces.
10. Attach a tubing assembly to each of the
ends of the poly tubing:
A. Take the end of one of the pieces of poly
tubing and slide a brass compression nut
over the end (small end first). See Figure 6.
B. Slide a white plastic compression sleeve
(large end first) over the end of the tub-
ing and into the nut.
C. Place a brass insert inside the end of the
tubing.
D. Connect the tubing assembly at the four
locations as shown in Figure 7.
NOTICE: The poly tubing will wear with
time. Replace tubing if necessary.
Large
end of
Compression
Nut
Brass
Ferrule
Tubing
Assembly
Ferrule
Union
Figure 7
For further operating, installation, or
maintenance assistance:
Large end
Call Omnifilter Customer Service
www.omnifilter.com
Delavan, WI 53115
Nut and Sleeve
Brass
Insert
3
Tubing
Assembly
Tubing
Assembly
Tubing
Assembly
at 800-937-6664;

Publicidad