• DRY CONTACT "
CONFIGURATION
IMPORTANT!: The function is available by
connecting the dry contact C3-C3 on the power
board and is active only if JUMPER MC4 is open.
The dry input contact (NC
types of operation that can be activated from the
T-EP remote control:
• Fireplace "FirE" function (default)
• Boiler "bOIL" function
From the main menu, access the "SEt" menu and
use the TOUCH PAD to display the "C3C3" menu.
Press the "Enter" key to confirm.
Use the TOUCH PAD to choose either the FirE
or bOIL function.
Confirm the selected function with the "Enter" key.
ENTER
NO*= normally open contact
NC*= normally closed contact
96
C3-C3
C3-C3
"
*
) C3-C3 enables two
ENTER
ENTER
• DRY CONTACT "
CONFIGURATION
IMPORTANT!: The function is available by
connecting contact FC-FC on the power board.
Contact FC-FC (230V output) enables two types of
operation that can be activated by means of the
T-EP remote control:
• "ALrN" function (default)
Remote alarm status signal
• "ConS" function 230V enabling signal for
synchronisation with external units.
From the main menu, access the "SEt" menu and
use the TOUCH PAD to display the "FrSt" menu.
Press "Enter" to confirm.
Use the TOUCH PAD to choose either the AlrN
or ConS function.
Confirm the selected function with the "Enter" key.
ENTER
fC-FC
fC-FC
"
ENTER