10

Technical specifications

Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Object with 90 % remission (based on standard white DIN 5033)
1
2
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
4
Usage category: AC-15, DC-13 (EN 60947-1)
5
With light / dark ratio 1:1
6
Signal transit time with resistive load
7
valid for Q\ on Pin2, if configured with software
8
Reference voltage DC 50 V
A = U
-connections reverse polarity protected
10
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
IP68: according to EN 60529 (water depth of 10 m / 24 h).
11
IP69K: according to ISO 20653:2013-03.
8021181.16B5 | SICK
Subject to change without notice
TECHNICAL SPECIFICATIONS
GRTE18(S)-
GRTE18(S)-xxx4xV,
xxx1xV, -xxx2xV
-xxx5xV
5 ... 100 mm
10 ... 400 mm
3 ... 115 mm
5 ... 550 mm
1
8 mm / 100 mm
9 mm / 400 mm
DC 10 ... 30 V
DC 10 ... 30 V
2
100 mA
100 mA
500 / s
500 / s
5
5
< 1 ms
< 1 ms
6
6
IP67, IP68,
IP67, IP68, IP69K
IP69K
11
III
III
8
8
A, B, D
A, B, D
10
10
-25 °C ... +55 °C
-25 °C ... +55 °C
ss
10
GRTE18(S)-xxx6xV,
-xxx7xV
10 ... 800 mm
5 ... 1,000 mm
1
1
45 mm / 800 mm
DC 10 ... 30 V
2
2
100 mA
500 / s
5
< 1 ms
6
IP67, IP68, IP69K
11
11
III
8
A, B, D
10
-25 °C ... +55 °C
13