Operating
Instructions
MSM
WARNING
Note
8 008 329/O371/05-04-04 © SICK AG • Industrial Safety Systems • Germany • All rights reserved
196
Override
Instructions for connection
The override function must only be activated by means of a
key-operated switch (with automatic reset and 2 indepen-
dent switching contacts for K 1 / K 2) in machine or
controller manual mode.
The override key-operated switch and the button for the
restart inhibit must not be identical.
The key-operated switch must be mounted such that the
hazardous area is in full view when operated.
The key-operated switch must be designed and connected
in conformance with EN 292 and EN 60 204.
Diagnostic facility
For software release see rating plate. If no software release is
printed on it, software release 1.8 applies.
£ sw 1.8
Online
Not possible
diagnosis
³ sw 1.9
Possible
Section 6