Troubleshooting
Before the pressing operation
Operating status
No LED lights up
Green LED flashes
During the pressing operation
Operating status
Green LED flashes
Green LED flashes and
roller drive moves back to
its starting position
Red LED flashes
Operating instructions ACO 201
Ensure the diameter of the press fitting matches the
1
diameter of the pressing jaw
Place the pressing jaw onto the press fitting, see the
2
operating instructions for the pressing jaws/pressing
collars
Press the start button and hold it for about two seconds
3
until the automatic pressing function activates
4
Wait until the roller drive moves back automatically
5
Release the pressing jaw from the press fitting
Cause
Actions
Standby mode
Press the start button for about two seconds
Accumulator is faulty
Have the accumulator checked and renew it if
necessary
Locking pin is not
Press the locking pin in as far as the stop
pushed in correctly
Cause
Actions
Accumulator not
• Charge the accumulator or renew it
charged up sufficiently
• Repeat the pressing operation
Locking pin has come
• Check the locking pin for damage
loose
• Press the locking pin in as far as the stop:
• Press start button
• Check the pressfitting for leaks and repeat the
Accumulator not
Charge the accumulator or renew it
charged up sufficiently
Start button was
• Press start button again: Roller drive moves to
released too soon
• Repeat the pressing operation: Press the start
Signal tone sounds and red LED lights up
pressing operation if necessary
its starting position
button for about two seconds