USA/Canada
Parts list for the Jøtul F 400
woodstove
Consult your dealer for part numbers and
replacement parts.
1
Ashlip
2
Door
2A
Gasket
2B
Glass clips
3B
Latch
4
Right side panel
5
Front panel
6
Top casting
7
Upper back panel
8
Smoke outlet
9
Back panel
10
Left side panel
11
Leg (long leg)
12
Upper bottom panel
13
Front door handle
14
Right burn plate
15
Glass panel
16
Airchamber
17
Air wash manifold
18
Top baffle (stainless steel)
19
Baffle cover (cast iron)
20
Air inspection cover
21
Rear burn plate
22
Fire brick (3)
23
Bottom grate
24
Left burn plate
25
Lower bottom panel
26
Ashpan housing
*
Ashpan
27
Air slider/valve
28
Air devider
30
Air control lever (chrome)
Allen head screw
31
Ashpan door
*
Ashpan door pin
32
Ash door handle
33
Baffle plate II
34
Latch compl.
*
Not shown
18
Appendix A
Alternate floor protection
All floor protection materials must be non-combustible ie. metal,
brick, stone, mineral fiber boards). Any combustible material may
not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow this
procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1.
Convert the specification to R-value;
a.
If R-value is given, no conversion is needed.
b.
If k-value is given with a required thickness (T) in inches:
R=1/k X T.
c.
If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor protector.
a.
Use the formula in Step 1 to convert values not expressed
as "R".
b.
For multiple layers, add R-values of each layer to determine
overall R-value.
3. If the overall R-value of the sustem is greater than the R-value of
the specified floor protector, the alternate is acceptable.
Example:
The specified floor protector should be 3/4" thick material with a k-
factor of 0.84. The proposed alternate is 4" brick with a C-factor of
1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications to R-value. R=1/
k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
•
4" brick of C-1.25, therefore
•
R brick = 1/C = 1/1.25 = 0.80.
•
1/8" mineral board of k = 0.29 therefore
•
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of 0.893.
Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
(hr)(ft
2
)(F)
(m
Thermal conductivity =
k = Btu
=
W
2
2
(hr)(ft
)(F)
(m
)(K)
Thermal resistance=
R =
Btu
=
(m
(hr)(ft
2
)(F)
The Jøtul F 400 Castine woodstove requires floor protection with a
minimum insulating r value of 0.5.
Alcove installation require a minimum r value of 1.6. (If a ul/ulc or
whi listed hearth pad is not used.)
W
2
)(K)
= (Btu)
(hr)(ft)(F)
2
)(K)
= (Btu)(inch)
W
(hr)(ft
2
)(F)