Check List - Jøtul GF 100 BF2 Instrucciones Para Instalación

Ocultar thumbs Ver también para GF 100 BF2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Important - before leaving the stove you must check:
1. All packaging materials are removed.
2. The correct gas jets (main & pilot) are fitted for the gas type and
pressure
3. Has the air regulator behind the burner been adjusted?
4. The correct gas pressure for gas type and model/fuel bed
type is checked and adjusted
5. Is the exhaust restrictor mounted according to the exhaust diagram?
6. The gas inlet pipe is not unnecessarily visible to the customer.
7. A suitable means of isolation is fitted to the inlet pipe.
8. Coal set: Has the secondary draught plate been removed?
9. Log set (vent system Ø100/170 mm: Has the secondary draught plate been
removed when the vertical exhaust height is 700 mm or more?
10. That the gas supply and all joints are sound.
11.That the horizontal flue has 2% incline
Date:___________________
Sign:_________________________________________
CORGI Reg.no. ________________________________

Check list

ENglish
Yes No
2

Publicidad

Tabla de contenido
loading

Tabla de contenido