Technical Data - Galletti MYCOMFORT LARGE Manual Del Usuario

Mando lcd para terminales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 94
MYCOMFORT LARGE
UNIT
TYPE
4-5-6-16-17-18-
2X1
-
28-29-30-34-35-36
AREO
-
1-2-3-25-26-27
CSW
-
1-2-3-13-14-15-25-26-27-31-32-33 WC66000079L
1-2-3-13-14-15-25-26-27-31-32-33
GB
ESTRO
-
7-8-9-19-20-21-37
FLAT
-
1-2-3-13-14-15-25-26-27-31-32-33
4-5-6-16-17-18-28-29-30-34-35-36
PWN
-
10-11-12-22-23-24-38
1-2-3-13-14-15-25-26-27-31-32-33
06-22
7-8-9-19-20-21-37
12/22 3-PH. 7-8-9-19-20-21-37
1-2-3-13-14-15-25-26-27-31-32-33
30
7-8-9-19-20-21-37
UTN
30 3-PH.
7-8-9-19-20-21-37
WH
-
1-2-3-13-14-15-25-26-27
2X1
-
ESTRO
-
FLAT
-
UTN
-
AREO
-
CSW
-
PWN
-
KP
WH
-
WARNING: in case modulating valve/s and/or modulating fan/s with inverter is/
are foreseen, to connect the two 0-10 V analog outputs of the control refer to the
drawings FC66002678 - pag 221 (presence of two modulating valves),
FC66003125 - pag 231 (presence of modulating fan), FC66003126 - pag 232
(presence of modulating fan + modulating valve).
Key to symbols used in wiring diagrams
Vo
Extra-low speed
V1
Minimum speed
V2
Medium speed
V3
Maximum speed
L
Phase
PE
Ground
N
Neutral
RE
Heating element
SW
Water sensor
SA
Air sensor
SU
Humidity Probe
BK
Black (Max. speed)
BU
Blue (Med. speed)
RD
Red (Extra low speed)
WH
White (common)
GY
Grey
BN
Brown (Min. speed)
GN
Green
YE
Yellow
MS
Flap microswitch
DI1
Digital 1 input
DI2
Digital 2 input
CI12
Digital input common
A-B-GND RS 485
F
Fuse (not supplied)
IL
Circuit breaker (not supplied)
CN
Terminal board
RHC
Heating/Cooling remote selecting switch
EXT
External auxiliary contact
KP
Circuit board to control 4 indoor units
IPM
Circuit board for UTN units
M
Fan motor
VHC
Solenoid valve –Cool/Heat.
VC
Solenoid valve - Cooling
VH
Solenoid valve - Heating
TSA
Automatic safety thermostat
TSM
Safety fuse
SC
Wiring box
.....
Electrical connections to be made by installer
FC66002638 - rev. 05
È severamente vietata la riproduzione anche parziale di questo manuale / All copying, even partial, of this manual is strictly forbidden
UNITS/ DIAGRAMS
CONFIGURATION (P00)
DIAGRAM
FC66002552L
FC66002553L
AP66000606L
FC66002554L
FC66002555L
FC66002551L
UT66000887L
UT66000890L
UT66000889L
UT66000892L
UT66000894L
UT66000888L
UT66000891L
UT66000893L
FC66002556L
FC66002557L
FC66002558L

TECHNICAL DATA

pages
214
Power supply
215
212
230
216
Operating temp.
217
Storage temp.
213
222
Protection rating
225
Control relay (Power outputs)
224
227
229
223
226
Connectors
228
Digital inputs
218
219
Analog inputs
Temperature sensors
220
Humidity probe
Configurable digital outputs (no-
voltage contacts)
ON-BOARD CONTROLLER INSTALLATION
The LCD controller can be installed directly (on both sides) on ESTRO, FLAT and 2x1
units using the controller kit provided, which contains:
-
Remote air temperature sensor (cable length 1.5 m)
-
LCD frame (to be added or replaced in case of flap)
-
Support for installation on the indoor unit
-
Reinforcement bracket (for Flat and 2x1 series)
-
Frame (for Estro series)
-
Sensor holder trap and clamp
NB: Prior to installation, carefully remove the protective film from the display; removal
of the film may cause some dark streaks to appear on the display but these will
disappear after a few seconds and are not signs of a controller defect.
FLAT
Installation on the support and fan coil unit
1. Remove the four screws concealed by the flap and take off the fan coil unit cabinet.
(Fig. 12).
Fig. 12 Removal of Flat cabinet
2. Open the controller after removing the screw of the cover; pass the cables through
the rear slot and wire them to the connectors as indicated in the diagram. Plug
in the connectors and close the controller again.
Fig. 13: Wiring cables of the controller
3. Pass the cables through the slot in the support and fasten the support and
controller together using the two screws provided. (Fig. 14 shows how the
controller and support are assembled together in the case of a controller mounted
on the right side of the fan coil unit; if the controller is mounted on the left side
the support must be turned by 180° compared to the drawing)
Fig. 14: Controller support fastening
4. Make the electrical connections according to the diagrams provided in this manual
(remove any connection cable for valve and heating element where these devices
are not present).
5. Once the electrical connections have been made, before completing installation
of the controller it is recommended to carry out the self-diagnosis procedure to
check whether all outputs are functioning correctly (fan at the different speeds
and valves where present). Refer to the relevant section in this manual.
6. Mount the controller-support assembly on the fan coil unit using the screws
provided.
Fig. 15 Fixing the support-Flat
7. Install the reinforcement bracket
Fig. 16 Reinforcement bracket
50
90-250Vac 50/60Hz
Electrical input 8W
Protection fuse 500mA delayed
Range 0-50
Range 10-60°C
IP30
NO 5A @ 240V (Resistive)
insulation: coil-contact distance 8 mm
4000V coil-relay dielectric
Max ambient temperature 105°C
250V 10°
NO-voltage contact
Closing current 2mA
Max. closing resistance 50 Ohm
Temperature and relative humidity
probes
NTC sensors 10K Ohm @25°C
Range 25-100
Resistive-type probe
Range 20-90%RH
5A @ 240Vac (Resistive)
3A @ 30Vdc (Resistive)
Max ambient temperature: 85°C

Publicidad