Siemens SIMATIC S7-1500 Manual De Usuario página 25

Ocultar thumbs Ver también para SIMATIC S7-1500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Web browser (external)
Any browser
OPC UA (external)
Any OPC UA client device
Any OPC UA server device
Add-ons to CPU 1505SP (F/T/TF), CPU 1507S (F), CPU 1508S (F) Version 2.6
A5E45929273-AD, 07/2019
Special features
Requirements
You have enabled the Web server.
You have enabled operation over the respective interface.
Via PC communication interface
IP address: As the connected Windows Ethernet interface
Port number: Configure as in the display application (default: 81/343)
Via runtime communication interface
With IP Routing or NAT Routing set up under Windows
IP address: IP address of the runtime communication interface
Port number: Default
With port forwarding set up under Windows
IP address: IP address of the Windows Ethernet interface
Port number: Default
Special features
Supported communication methods
Data access to any (configured) data
Method call
Requirement
You have enabled OPC UA.
Addressing the CPU via external client
With IP Routing or NAT Routing set up under Windows
IP address: IP address of the runtime communication interface
IP port: Default
With port forwarding set up under Windows
IP address: IP address of the connected Ethernet interface
IP port: Default
Note: Some OPC UA clients do not support operation via port forwarding.
Addressing of the external server via CPU client
With IP Routing or NAT Routing set up under Windows
IP address: IP address of the external client
IP port: Default
With port forwarding set up under Windows
IP address: IP address of the Siemens RT-VMM network adapter
IP port: Default
25

Publicidad

Tabla de contenido
loading

Tabla de contenido