1
3
Fig. 7:
Control cabinet
1 Frequency drive
2 Braking resistor
3 Logic board
4 RFI filter
5 Transformer
DANGER: Risk of electric shock from live
parts
Touching the frequency drive or the braking
resistor may result in electric shock even
after the mains supply is switched off.
Disconnect the mains supply.
Do not touch the frequency drive or the
braking resistor for 10 minutes after
switching off the mains supply.
Robert Bosch GmbH
2
4
5
Product description | EPS 625 | 47
Fig. 8:
Side view of the control cabinet
1 "Mains on" indicator
2 MGT illumination switch
3 Master switch
The master switch (Fig 8, Pos 3) and MGT illumination
switch (Fig 8, Pos 2) are located on the side of the con-
trol cabinet.
i
The bushing (Fig. 1, Pos. 8) acts as a lead-through
for an additional 230 V AC power supply at the
switch cabinet. Customer service must be called
in for wiring up the 230 V AC power supply in the
switch cabinet. Do not alter the wiring in the switch
cabinet. Bosch cannot accept any liability for dam-
age resulting from inexpert workmanship.