BTL7-S5_ _(B)-M _ _ _ _ -P-S32/KA _ _/FA_ _
Transducer – Profile style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The transducer, together with a machine controller (e. g.
PLC), comprises a position measuring system. It is
intended to be installed into a machine or system and used
in the industrial sector. Flawless function in accordance
with the specifications in the technical data is ensured only
when using original Balluff accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists with basic electrical knowledge.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
Dimensions and function
The transducer contains the waveguide which is protected
by an aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined. The magnet defines
the position to be measured on the waveguide.
3)
12
72
Groove
~80
~23
max. 7
1
english
Nominal length =
Measuring range
4)
~250
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
Dimensions and function (continued)
LED 1
Operating state
Green
Normal function
Red
Error
LED 2
Operating state
Synchronous operation 2)
Green
Asynchronous operation 2)
Off
Flashing green
Programming mode
1) Not for BTL7-...-FA_ _
2) Asynchronous operation is reached when the external sampling rate is
> f
or < 62.5 Hz (only with BTL7-S5_ _B-...).
A,max
Installation
Improper installation
Improper installation can compromise the function of the
transducer and result in damage.
► For this reason, ensure that no strong electrical or
magnetic fields are present in the immediate vicinity
of the transducer.
► The recommended spacing for the installation must
be strictly observed.
Any orientation is permitted. Mount the transducer on a
level surface of the machine using the provided mounting
clamps and cylinder-head screws. A sufficient number of
mounting clamps is supplied.
In order to avoid the development of resonant
frequencies from vibration loads, we
recommend arranging the mounting clamps at
irregular intervals.
3)
73
~250
~80
15
3) Unusable area
4) Not included in scope of delivery
File no. 1)
E227256