Downloading Further Instructions - Balluff BTL7-S5 Serie Instrucciones Breves

Ocultar thumbs Ver también para BTL7-S5 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-SA360-KA _ _ -ZA10
Micropulse Transducer - Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete standard user's guide can be downloaded
from the Internet at www.balluff.com or requested via
e-mail from service@balluff.de.
Mounting surface
BTL7...SA360-KA_ _-ZA10
13.5
Ø 4.4
2) Unusable area
3) Not included in scope of delivery
Version
...-A/B/Y/Z-...
...-A8/B8/Y8/Z8-...
www.balluff.com
B: 30-1 mm
Z: 2"-0.04"
2)
Magnet
BTL7...B/Z...
0.5 Ø 25
Thread size
B: M18x1.5
71
25
Z: 3/4"-16UNF
D1
G
10.2 mm
Thread
M4x4/6 deep
8 mm
No thread
Dimensions and function
The BTL7 transducer contains the waveguide which is
protected by an outer stainless steel tube (rod). A magnet
is moved along the waveguide. This magnet is connected
to the system part whose position is to be determined.
LED 1
G
een
Normal function
r
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Green
Synchronous operation 1)
Internal measurement is synchronous to SSI query.
Off
Asynchronous operation 1)
Internal measurement is asynchronous to SSI query.
Flashing
Programming mode
green
Only with BTL7-S510(B)-...
1) Asynchronous operation is reached when the external sampling rate
is > f
or < 62.5 Hz (only with BTL7-S5_ _B-...).
A,max
KA00,09 = 0.09 m cable length
Damping zone
60
Nominal length =
Measuring range
3)
Mounting surface
A: 30-1 mm
Y: 2"-0.04"
2)
71
25
File no.
E227256
2)
46
45
LED 1
LED 2
3)
BTL7...A/Y...
Thread size
A: M18x1.5
Y: 3/4"-16UNF
english
1

Publicidad

Tabla de contenido
loading

Tabla de contenido