Fig. 2: Attachment point
5.3

Storage

Installation and operating instructions Wilo-Padus PRO
Transportation and storage
WARNING
Head and foot injuries due to a lack of protective equipment!
Danger of (serious) injuries during work. Wear the following protective equipment:
• Safety shoes
• Safety helmet must be worn if lifting equipment are used!
NOTICE
Use only properly functioning lifting equipment!
Use only properly functioning lifting equipment to lift and lower the pump. Ensure
that the pump does not become jammed during lifting and lowering. Do not exceed
the maximum bearing capacity of the lifting equipment! Check that lifting equip-
ment is functioning properly before use!
CAUTION
Soaked packaging may tear!
The product may fall on the ground if unprotected and may be damaged. Lift wet
packaging carefully and replace it immediately!
Only remove the outer packaging at the place of utilisation to ensure that the pump is
not damaged during transport. Use tear-proof plastic sacks of sufficient size to pack-
age used pumps for transport in a leak-proof manner.
The following points must also be observed:
▪ Adhere to the applicable national safety regulations.
▪ Use legally specified and approved lifting gear.
▪ Select the lifting gear based on the existing conditions (weather, attachment point,
load, etc.).
▪ Only attach the lifting gear to the attachment point. Fix with a shackle.
▪ Use lifting equipment with sufficient bearing capacity.
▪ The stability of the lifting equipment must be ensured during operation.
▪ When using lifting equipment, a second person must be present to coordinate the pro-
cedure if required (e.g. if the operator's field of vision is blocked).
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
CAUTION
Total damage due to moisture ingress
The ingress of moisture into the connection cable damages the cable and the pump!
Never immerse the ends of the connection cable in fluid. Seal them tightly during
storage.
Newly delivered pumps can be stored for one year. Contact customer service before
storing the device for more than one year.
When storing the pump, please note the following points:
en