9.2

Operator responsibilities

9.3

Operating fluid

9.3.1
Oil types
9.3.2
Filling quantities
9.4

Maintenance intervals

9.4.1
Maintenance intervals for normal
conditions
9.4.2
Maintenance intervals for harsh
conditions
9.5

Maintenance measures

Installation and operating instructions Wilo-Padus PRO
Maintenance and repair
▪ Maintenance tasks: The technician must be familiar with the use of operating fluids and
their disposal. In addition, the technician must have basic knowledge of mechanical en-
gineering.
▪ Provide the necessary protective equipment and make sure that the personnel wears it.
▪ Collect operating fluids in suitable tanks and dispose of properly.
▪ Dispose of protective clothing used in accordance with regulations.
▪ Use only original parts of the manufacturer. Use of parts other than the original parts
releases the manufacturer from any liability.
▪ Collect any leakage of fluid and operating fluid immediately and dispose of it according
to the locally applicable guidelines.
▪ Provide the tools required.
▪ If flammable solvents and cleaning agents are used, open flames, naked lights and
smoking are prohibited.
Medicinal white oil is filled into the sealing chamber ex-factory. The following oil types
are recommended when changing the oil:
▪ Aral Autin PL*
▪ Shell ONDINA 919
▪ Esso MARCOL 52* or 82*
▪ BP WHITEMORE WOM 14*
▪ Texaco Pharmaceutical 30* or 40*
All oil types marked with "*" are approved for use with foods in accordance with
"USDA-H1".
The filling volumes are:
▪ Padus PRO M05: 800 ml (27 US.fl.oz)
▪ Padus PRO M08: 1250 ml (42 US.fl.oz)
To ensure reliable operation, maintenance tasks must be carried out regularly. Depend-
ing on the real ambient temperatures, maintenance intervals different from those men-
tioned in the contract can be defined! If strong vibrations occur during operation, the
pump and the installation must be checked regardless of the defined maintenance in-
tervals.
4000 operating hours
▪ Visual inspection of the connection cables
▪ Visual inspection of accessories
▪ Visual inspection of the housings for wear
▪ Function test of monitoring devices
▪ Oil change
15000 operating hours
▪ Complete overhaul
Under harsh operating conditions, specified maintenance intervals must be shortened if
required. Harsh operating conditions include:
▪ Fluids with long-fibre components
▪ Turbulent inlet (e.g. due to air intake, cavitation)
▪ Strongly corroding or abrasive fluids
▪ Heavily gas generating fluids
▪ Operation at an unfavourable duty point
▪ Pressure surges
When using pumps under hard conditions, it is recommended to sign a maintenance
contract. Contact customer service.
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
en