3 Commissioning

3.1 Switching on and off

The plug socket on the vacuum cleaner will always be live when the
mains plug is plugged in, irrespectively of the position of the switch.
l CAUTION!
Electric tools and compressed air tools must be switched off
when they are connected
If the switch is in the >0< position, the plug socket on the vacuum
cleaner can be use as an extension lead.
l Connection value: Vacuum cleaner + connected unit,
maximum 16 A.
l CAUTION!
Selector switch for minimum material flow (horn and light)
on vacuum cleaners classes "M" and "H"
In the modes >A< and >RA< the following setting is made,
depending on the diameter of the hose:
Inside diameter of the hose
∅ 35 mm
∅ 27 mm
∅ 21 mm
No speed regulation is carried out.
The vacuum cleaner always runs at max. speed.
▷ Push the plug of the vacuum cleaner into the plug socket.
▷ Set the desired operating mode on the switch.
↳ The vacuum cleaner is ready for suction.
▷ After vacuum cleaning, set the switch to "O".
↳ The vacuum cleaner is switched off.
▷ Pull the mains plug of the vacuum cleaner out of the plug socket.
▷ Secure the mains cable.
▷ Remove the electric/compressed air tool.
▷ Fix the suction hose in the accessory storage location* on the
back of the container for storage.
▷ The ends of the hose can be pushed into each other to prevent
particles of dirt from coming out.
(* depending on the equipment variant)
4 Operating modes
When using the grip handle you can adapt the suction performance
by using the slider to control access of air into the hose.

4.1 Dry vacuum cleaning

You should only use the vacuum cleaner with a dry filter and
appropriate accessories to prevent dust from accumulating and
forming encrustations.
When using the vacuum cleaner to remove soot, cement, plaster,
flour or similar dust we recommend using fleece filter bags. Always
use filter bags in combination with folding filter cassettes.
24 - GB
NOTE
Switch position
70 m
/h
3
40 m
/h
3
20 m
/h
3
M, H and H Asbestos class vacuum cleaners should be
preferably used as dry vacuum cleaners.

4.2 Wet vacuum cleaning

l CAUTION!
Switch the vacuum cleaner off immediately if foam or liquid starts
to come out.
Empty the container and, if necessary, the folding filter
cassette.
Clean the water level sensors (1) regularly
and examine for signs of damage.
1
1
▷ Vacuum cleaning without paper filter bags.
The folding filter cassettes are designed for wet vacuum
cleaning.
The fitted sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be compromised
by a full container.
▷ Empty the vacuum cleaner
l CAUTION!
If the vacuum cleaner is not switched off, the re-start protection
unit remains operative. Only after switching off and re-starting is
the vacuum cleaner ready for use again.
▷ Remove the suction hose from the liquid before emptying.
▷ After switching off, a small quantity of water can flow back out of
the hose, as a result of the high suction level and the favourable
flow condition in the container.
▷ If you use it as a dry vacuum cleaner, you must insert dry filters.
If you change between dry and wet vacuum cleaning frequently,
we recommend using a second set of filters, preferably polyester
folding filter cassettes.
5 Cleaning the filter
The suction unit is fitted with an electro-magnetic filter cleaning
device which can shake off any dust adhered to the folded filter
cassettes.
5.1 Cleaning the filter
The vibration function (switch setting R or RA /switch ②a) should
be activated at the latest when the volume flow display ②c (warn-
ing lamp) lights up or when the warning signal sounds or when the
suction output sinks.