RoUTINE mAINTENANCE (AFTER RUNNING-IN)
"Periodic maintenance operation record sheet" provided, so as to keep a trace of
GB
the operations performed and therefore establish the most suitable methods for
future operations.
Frequency
()
Every 0

hours

Every 300
hours (6)
English
Type of inter-
Component
vention
Engine oil (2)
Level control
Coolant (4)
Level control
Check it is
clean
Air filter
Check the clog-
ging indicator
that is installed
on the filter body
Coolant fluid
Check it is
radiator
clean
Engine oil (2)
Replace
(6)
Replace the
Oil filter
cartridge
Replace the
main cartridge
Air filter
Check if the
safety cartridge
is clean
Fuel filter
Replace
Check it is
Air intake circuit
clean
and intercooler
Check of pipe
pipe
sealing
Dust discharge
Check it is
circuit
clean
Oil separation
Check of pipe
circuit
sealing
Check of pipe
Vacuum circuit
sealing
R750EU5 - IE3 - TE4 - IE4 - ISE4
For each maintenance operation, fill in the
Intervention
procedures
Top up, if nec-
essary
Top up, if nec-
essary
Clean with low
pressure com-
pressed air.
Clean the filter
or, if necessary,
replace it with a
new one.
Clean with a
soft brush
Clean with low
pressure com-
pressed air.
38
Reference
See "Engine oil
level control"
See "Engine
coolant level
check"
See "Cleaning
and replacement
of the air filter"
See "Engine oil
change"
See "Oil filter
cartridge re-
placement"
See "Cleaning
and replacement
of the air filter"
See "Cleaning
and replacement
of the air filter"
See "Fuel filter
replacement."
Ed.8 / 0-202