Bradley Terreon TDB3108 Instalación página 18

Ocultar thumbs Ver también para Terreon TDB3108:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TDB3108, WF3208 Terreon
6
Electrical connections for Adaptive Infrared
START-UP NOTE: Do not use for two minutes after making power connection. The sensors will take up
to eight minutes (without being used) to adapt to the bowl if another object is detected during the
two-minute start-up period.
CONNECT THE THREE WIRES FROM THE INFRARED MODULE ASSEMBLY TO THE VALVE ASSEMBLY. ATTACH TWO OF THE FEMALE
A
CONNECT WIRES TO THE SOLENOIDS AS SHOWN IN FIGURE 12. ATTACH THE MALE CONNECT WIRE TO ONE OF THE 24 VAC
TRANSFORMER LEADS. ATTACH THE REMAINING TRANSFORMER LEAD TO THE SOLENOID WIRE ADAPTER (SEE FIGURE 12).
B
CONNECT 24 VAC TRANSFORMER PROVIDED TO POWER SOURCE.
C
TURN SUPPLIES ON. OPEN CHECK/STOP VALVES COMPLETELY.
D
OPEN VOLUME CONTROL VALVE COMPLETELY AND CHECK PIPING INSTALLATION FOR LEAKS.
E
PASS YOUR HAND IN FRONT OF EACH SENSOR UNTIL AIR IS PURGED FROM THE LINES.
WINDOW
269-1351
(S53-272) B
BLACK
(S53-261A) C
RED
ADAPTER
Figure 12
18
®
54" Circular
I.R. MODULE
S50-344
WIRE
269-620
4/6/2007
TOP VIEW MODULE
(S53-261A) A
ASSEMBLY
RED
CONNECT WIRES
AS SHOWN
VALVE ASSY.
S50-369
S53-261
Bradley Corporation • 215-1187 Rev. N; EN 06-915B
110/24 VAC
TRANSFORMER
S83-134
F = FEMALE CONNECT
M = MALE CONNECT
Installation

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Terreon wf3208

Tabla de contenido