Pressure Setting - Goetze 2140 Manual De Instrucciones

Tabla de contenido

Publicidad

7

Pressure setting

Maintenance intervals depend on the operating conditions and must be determined by the
operator. If deviations from the normal condition are detected during maintenance (e.g.
leakages, incorrect pressure control, noises, etc.), the shut-off valves must be replaced im-
mediately or professionally repaired, in order to ensure continued safe operation.
Repairs to shut-off valves must be performed only by Goetze KG Armaturen or by authorised
specialist workshops, using only genuine spare parts. Makeshift repairs of any kind are not
permitted!
Fault
Leak from the
spindle
Leak between
upper section and
housing
Leak from the seat
Valve does not
open / close
Assembly and maintenance instructions - 2140 / 2180
Possible cause
Spindle seal leaky
Gland nut loose
Gland packing defective
Fitting / surface of spindle damaged
Valve upper section loose
Seal damaged
Foreign bodies between the disc
and seat
Seat damaged
Cone assembly seal damaged
Thread stuck, damaged
Handwheel defective, damaged
Solution
Remove the screw (pos. 8)
Remove the handwheel (pos. 9)
Undo the lock nut (pos. 10)
Retighten the gland nut (pos. 11)
Tighten the lock nut (pos. 10)
Detach the handwheel (pos. 9)
Tighten the screw (pos. 8)
Replace the gland packing
Replace upper section
Tighten the screws to the specified
tightening torque
Replace the seal
Remove foreign bodies, flush and
clean system
Replace housing
Replace seal
(together with cone, if necessary)
Replace housing
Replace spindle + handwheel
www.goetze-armaturen.de

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2180

Tabla de contenido