Table 3 For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING
The [BPW-1005] is intended for use in the electromagnetic environment specified below.
The customer or the user of the [BPW-1005] should assure that it is used in such an environment.
Immunity test
ction.
ly to
s
Radiated RF
IEC 61000-4-3
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones
a
and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be
tile.
predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF
l, the
transmitters, an electromagnetic site survey should be considered. If the measured field strength in
the location in which the [BPW-1005] is used exceeds the applicable RF compliance level above, the
[BPW-1005] should be observed to verify normal operation. If abnormal performance is observed,
at
additional measures may be necessary, such as re-orienting or relocating the [BPW-1005].
a
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.
b
t.
Guidance and manufacturer's declaration - electromagnetic immunity
IEC 60601
test level
3 V/m 80
MHz to 2.5
GHz
absorption and reflection from structures, objects and people.
Compliance
level
Portable and mobile RF communications
equipment should be used no closer to any part
of the BPW-1005, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
the transmitter.
Recommended separation distance:
—
d = 1.2 √
P 80 MHz to 800 MHz
—
d = 2.3 √
P 800 MHz to 2.5 GHz
3 V/m
Where P is the maximum output power rating
of the transmitter in watts (W) according to
the transmitter manufacturer and d is the
recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,
should be less than the compliance level in each
frequency range.
Interference may occur in the vicinity of
equipment marked with the following symbol:
15 15
Electromagnetic
environment - guidance
b
a