Installation and User Manual
2.14. Cables and fuses for heaters 1101 – XX (SKLA / Magma) and sensor OLET 31
installation location
Model
1101 – 181 / 1811
1101 – 210 / 2101
1101 – 260 / 2601
Table 3. Cables and fuses for heater 1101 – XX (SKLA / Magma)
2.15. Safety clearances for sauna heaters 1101 – XX (SKLA / Magma)
and sensor OLET 31 installation location
2
3
H
D
9
1
4
Max
500 mm
Figure 6. Installation location of the OLET 31
sensor 40 mm from the ceiling in the centre of
the heater. The safety distance between the
heater and the wall behind the heater must be at
least the minimum distance listed in tables 4
1. Contactor box WE - 50
2. Sensor OLET 31
3. Temperature resistant cable for sensor
4. Feed cable to the sauna heater
5. Connection box
6. Connection cable to the sauna heater
7. Lower bench or railing
8. Upper bench or railing
9. Control centre Pure or Elite
Figure 8. Safety clearances
MAGMA
and
Sauna heaters
connection cable
Power
H07RN-F /
60245 IEC 66
kW
mm
400V – 415V 3N~p
2 – Power group
18 (9 + 9)
2 x (5 x 2,5
21
5 x 2,5
(9 + 12)
5 x 6
26
2 x (5 x 6)
(13 + 13)
40 mm
F
A
Min
50 mm
SKLA
Fuse
2
A
2 x (3 x 16)
3 x 16
3 x 25
2 x (3 x 25)
H
8
7
Figure 7. Alternative installation location
of the OLET 31 sensor on a ceiling in
the centre above the heater.
1101 - ... Magma / SKLA
Note! Alternative installation location of
the OLET 31 sensor on a ceiling in the
centre above the heater
Sauna heaters
connection cable
H07RN-F /
60245 IEC 66
2
mm
230V 3~
2 – Power Group
2 x (4 x 6)
2 x (3 x 25)
4 x 6
4 x 10
WE - 52
WE - 52
2 x (4 x 10)
2 x (3 x 35)
WE - 52
WE - 52
2
F
D
C
5
6
10
Fuse
A
3 x 25
3 x 35