TROUBLESHOOTING

Symptoms
None of the indicators that
indicate the state of charge
are switching on
The charger is properly
connected but it does not
charge the battery
The fuse blows every time it
is replaced
After charging for a whole
day, the end of charge
indicator does not switch on.
START UP 80
Causes
No mains voltage
Clamps in short circuit or polarity
reversal.
Bad clamp connections.
Wrong charge settings
Following intensive use, your
device has entered thermal
protection mode.
Polarity reversal
Wrong charge settings
Current overconsumption on the
battery
The battery is damaged
Remedies
Check that the power cord is plugged to a
230V 50/60Hz socket. Check the power supply
network.
Remove the clamps. Check that the fuses have
not melted and that the circuit breaker is not
tripped
Clean the terminals and the clamps. Check the
state of the cables and clamps.
Check that the selected voltage matches the
battery voltage.
Wait 1/4h so the device can cool down.
Connect the + clamp to the battery's (+) and
the + clamp to the battery's (-).
Check that the selected voltage matches the
battery voltage.
Do not draw any of the battery's current during
the charge
Change the battery.