1.3. TECHNICAL SPECIFICATIONS
Primary side
Primary power supply
Primary power supply frequency
Effective primary consumption
Maximum primary consumption
Fuse primary
Maximum apparent power
Maximum active power
Active power in standby (IDLE)
Efficiency at maximum current (MIG)
Power factor at maximum current (MIG)
Cos Phi
Secondary side
No load voltage (according standard)
Welding range Max MIG
Welding range Max MMA
Duty cycle at 100%
(10 min cycle at 40°C)
en MIG
Duty cycle at 60%
(6 min cycle at 40°C)
en MIG
Duty cycle at maximum current at 40°C
Miscelleanous
Dimensions (Lxwxh)
Weight
Operating temperature
Storage temperature
Torch connection
Protection index
Insulation class
Standard
WARNING: This power source cannot be used in falling rain or snow. It may be stored outside, but it is not designed for use
without protection during raining.
DIGISTEEL III / DIGIPULS III 420-520
DIGISTEEL III 420
W000383615
50/60Hz
25 A Gg
18 KVA
17,2 KW
en MIG
14,8V / 35 V
15A / 420A
15A / 420A
en MIG
720 x 295 x
-10° C / +40° C
-20° C / +55° C
"Européen"
60974-1 &
60974-10
DIGISTEEL III 520
W000383617
400 V
400 V
50/60Hz
18,5 A
28,5 A
26 A
33,9 A
32 A Gg
23,8 KVA
22,4 KW
28 W
29 W
87
89
0,96
0,94
0,99
0,99
57 V
73 V
14,8V / 39 V
15A / 500A
15A / 500A
350A
450A
380A
500A
40%
60%
720 x 295 x
525
525
34 kg
40 kg
-10° C / +40° C
-20° C / +55° C
"Européen"
IP 23
IP 23
H
H
60974-1 &
60974-10
DIGIPULS III 420
DIGIPULS III 520
W000383661
W000383662
400 V
400 V
50/60Hz
50/60Hz
28,5 A
21,1 A
27,1 A
33,9 A
25 A Gg
32 A Gg
18,9 KVA
23,8 KVA
17,7 KW
22,4 KW
29 W
29 W
87
89
0,93
0,94
0,99
0,99
73 V
73 V
14,8V / 35 V
14,8V / 39 V
15A / 420A
15A / 500A
15A / 420A
15A / 500A
450A
350A
500A
420A
60%
60%
720 x 295
720 x 295 x
x 525
525
36 kg
40 kg
-10° C / +40° C
-10° C / +40° C
-20° C / +55° C
-20° C / +55° C
"Européen"
"Européen"
IP 23
IP 23
H
H
60974-1 &
60974-1 &
60974-10
60974-10
EN
5