Setup location requirements:

In order to ensure the safe and trouble-free operation of the device, the setup location
must fulfil the following prerequisites:
The device must be set up on a firm, flat, horizontal and heat-resistant surface with
sufficient load-bearing capacity for the device and the maximum weight of the
expected food that is to be prepared in the device.
Choose the setup location in such a way that children cannot reach any hot surfaces on
the device.
Do not set up the device in a hot, wet or extremely damp environment or near
flammable material.
This device is only suitable for installation in a cabinet, not as a free-standing device
and not in a closed cabinet.
The installation and assembly of this device in non-stationary setup locations (e.g. on
ships) must be carried out by specialist companies / electricians, provided they
guarantee the prerequisites for the safe use of this device.

11.9 Electrical connection

In order to ensure the safe and trouble-free operation of the device, the following
instructions must be observed for the electrical connection:
Before connecting the device, compare the connection data (voltage and frequency) on
the rating plate with those of your electrical network. This data must agree in order that
no damages occur in the device
If in doubt, ask your qualified electrician.
The connection between the device and the electrical network may employ a 3 meter
long (max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs
or gangs is prohibited because of the danger of fire that is involved with this.
Make sure that the power cable is undamaged and has not been installed under the
device or over hot or sharp surfaces.
The electrical outlet must be protected by a 16A safety cut-out switch, separately from
other electricity consumers.
In case the plug is no longer accessible after installation, a circuit breaker disconnecting
all electrical poles with a distance of at least 3 mm between contacts must be present in
the line.
The electrical safety of the device is only guaranteed if the device is connected to a
properly installed protective conductor system. If in doubt, have the house installation
checked over by a qualified electrician. The manufacturer cannot be made responsible
for damages that are caused by a missing or damaged protective conductor.