• The surface of the bowl may change color after first use or with prolonged
use. This color change is the effect of steam and water—it will not affect
the use of the multicooker and is not hazardous to your health. You can
continue to use it safely.
Cleaning the inner lid
Remove the inner lid by pushing outwards with both hands (fig.3). Clean it
with a sponge and washing up liquid (fig.4). Then wipe dry and put it back
behind the 2 ribs and push it on the top until it's fixed – (fig.7–8).
Cleaning and care of the other parts of the appliance
Clean the outside of the multicooker – fig.6, the inside of the lid and the
cord with a damp cloth and wipe dry. Do not use abrasive products.
Do not use water to clean the interior of the appliance body as it could
damage the heat sensor.
TECHNICAL TROUBLESHOOTING GUIDE
Malfunction
Causes
description
Control panel
Appliance not
lights off and
plugged in.
no heating.
Problem of the
Control panel
connection of the
lights off and
indicator light or
heating.
indicator light is
damaged.
Lid is badly closed.
Steam leakage
Inner lid not positioned
during use.
or assembled properly.
The sealing gasket is
damaged.
118
Solutions
Check the appliance is
plugged in the socket, and
is switched on.
Send to authorized service
center for repair.
Open and close the lid
again.
Ensure the inner lid is well
positioned –
fig.7-8
Send to authorized service
center for repair.
Malfunction
Causes
description
Rice
Too much or not
undercooked or
enough water compared
overcooked.
to rice quantity.
Rice
undercooked or
Insufficiently simmered.
overcooked.
The keep warm function
Automatic keep
has been cancelled by
warm function
user during the setting.
fails
The function may only
(appliance stays on
cooking programe
operate after Porridge,
or does not heat on
Soup, Stew, Rice/
.
keep warm)
cereals menus.
The sensor on the top
E0
open circuit or short
circuit.
The sensor on the
E1
bottom open or short
circuit.
Remark: If inner bowl is deformed, do not use it anymore and get a
replacement from the authorized service center for repair.
Solutions
Refer to rice cooking table
for water quantity.
Always add rice to the
cooking bowl first, then
EN
add water to the water
level mark on the inside of
the bowl.
Send to the authorized
service center for repair.
Stop the appliance and
restart the program. If the
problem repeats, please
send to the authorized
service center for repair.
119