10
Maintenance
11
Technical data
8025247.1ABI / 2020-12-18 | SICK
Subject to change without notice
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
WFE
-030xxxxxxx
Fork width
30 mm
Smallest
detectable object
(MDO)
Type of light
Supply voltage U
B
Ripple
Power consump‐
tion
2)
Switching output
Output current
I
max.
Voltage output
Hysteresis
Switching fre‐
quency
Max. response
time
Stability of
response time
Initialisation time
Enclosure rating
-050xxxxxxx
-080xxxxxxx
50 mm
80 mm
0.5 mm
Visible red light
10 ... 30 V DC
1)
< 10%
< 20 mA
Push Pull
100 mA
Push/pull: High = V
- < 2 V / Low: ≤ 2V
S
< 0.1 mm
-120xxxxxx/-180xxxxxx: <0.2mm
5 kHz
3)
100 μs
4)
± 20 μs
100 ms
IP 65 / IP 67
10
MAINTENANCE
-120xxxxxxx
-180xxxxxxx
120 mm
180 mm
9