Commissioning
2
8017528 | SICK
Function reserve
1,000
100
1
10
2
3
1
5
10
15
(16.4)
(31.8)
(49.2)
Image 1: H
2
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK range
of accessories). Align the sender and receiver with each other.
Note the sensor's maximum permissible tightening torque of < 0.5 Nm.
3
The sensors must be connected in a voltage-free state (V
graphics [B] must be observed, depending on the type of connection:
– Male connector connection: pin assignment
– Cable: core color
Image 2: B
Only apply voltage/switch on the power supply (V
have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching output Q (according to Graphic B):
WS/WE100-2P (PNP: load -> M)
L = light switching
D = dark-switching
4
Align the sender with the receiver. Select the position so that the red emitted light beam hits
the receiver. Tip: Use white paper or a reflector as an alignment aid. The sender must have
a clear view of the receiver, with no object in the path of the beam [see E]. You must ensure
that the optical openings (front screen) of the sensors are completely clear.
1 With slotted mask, width 2.0 mm
2 With slotted mask, width 1.0 mm
3 With slotted mask, width 0.5 mm
Sensing range
20
25
30
35
(65.6)
(82.0)
(98.4)
(114.8)
Distance in m (feet)
> 0 V) once all electrical connections
S
= 0 V). The information in the
S