Connecting The Coolant - Abicor Binzel ABIPLAS WELD 250 MT Instructivo De Servicio

Ocultar thumbs Ver también para ABIPLAS WELD 250 MT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIPLAS
WELD 250 MT

6.4 Connecting the coolant

1
Coolant return hose
Fig. 7
Connecting the coolant
NOTE
• Only pure inert gases or their mixtures may be used as the plasma gas.
2 Connect the plasma and shielding gases correctly.
3 Connect pilot power plug to power source.
NOTE
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, coolant return = red.
• Do not use deionized or demineralised water as coolant or for tightness
and flow tests.
• For liquid-cooled welding torches, we recommend using the
ABICOR BINZEL coolant BTC-15.
1
2
Coolant supply hose
Charge the entire cooling system as follows when used for the first time and
after every cable assembly change:
1 Disconnect the coolant return hose (1) from the re-circulating
cooling unit (2) and hold it over a collecting device.
2 Close the opening at the coolant return hose (1) and open it again by
repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles into the collecting device.
3 Switch off the re-circulating cooling unit (2) and reconnect the coolant
return hose (1) .
2
3
Re-circulating cooling unit
6 Putting into operation
3
EN - 13

Publicidad

Tabla de contenido
loading

Tabla de contenido