Roger Technology B70/2DC Instrucciones Y Advertencias Para El Instalador página 57

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 116
CONTACT
20(COS2)
22(COM)
21(COS1)
22(COM)
23(ST)
22(COM)
24 (ANT)
25
27(ORO)
26(COM)
28(AP)
32(COM)
29(CH)
32(COM)
30(PP)
32(COM)
31(PED)
32(COM)
RECEIVER CARD
BATTERY CHARGER
B71/BC
DESCRIPTION
Auxiliary input for connecting either a sensing edge COS2 or a gate open limit switch on
1. A sensing edge COS2 in addition to COS1.
. The sensing edge COS2 (NC contact) is disabled.
2. If the sensing edge is not installed, jumper the terminals 20(COS2) - 22(COM) or set
the parameter
.
mit switch on LEAF 2. The gate open limit switch for LEAF 2 is disabled by default
Input (NC or 8 kOhm) for connecting sensing edge COS1
. If the sensing edge COS1 (NC contact) is enabled, the gate always reverses.
If the sensing edge is not installed, jumper the terminals 21(COS1) - 22(COM) or set the
parameter
.
STOP command input (NC).
The current manoeuvre is arrested if the safety contact opens.
N.B.:
N.B.: do not make joints in cable.
Auxiliary input for connecting either a timer clock contact ORO or a gate open limit switch
1. Clock timer contact input (N.O.).
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock) the gate closes.
2.
limit switch on LEAF 1. The gate open limit switch for LEAF 1 is disabled by default
.
Open control signal input (N.O.).
Close command input (N.O.).
Step by step mode command input (N.O.).
The function of the control is determined by parameter
Partial open control signal input (N.O.).
On double leaf gate automation systems, by default, the partial opening command opens
LEAF 1 completely.
With single leaf swing gate installations, by default, partial opening is 50% of total ope
ning.
The control unit has two radio remote control functions by default:
In the event of a mains power loss, the control unit is powered by the batteries. When
battery power is used,
at intervals until mains power is restored or until the battery voltage drops below the
minimum permissible limit. In this case,
the control unit accepts no commands.
If mains power is lost while the gate is moving, the gate stops and then automatically
resumes the interrupted manoeuvre after 2 seconds.
.
(Battery Low) is shown on the display and
), gate open li
.
), gate open
57

Publicidad

Tabla de contenido
loading

Tabla de contenido