Cleaning/replacing the quartz glass
The quartz glass is fastened in the filter head by a rotor cover so that no water can leak from the
container interior.
Replace the quartz glass if it is scratched or has become opaque. Otherwise the cleaning
power of the UVC lamp is no longer sufficient.
CAUTION
The quartz glass and UVC lamp could break and cause cuts.
Act with caution when performing work on the UVC clarifier in order to avoid cuts.
Avoid shocks, impacts and abrupt movements to prevent the glass from breaking.
Prerequisite:
The UVC unit head has been removed. (→ Removing the UVC unit head)
How to proceed:
Switch off the filter pump.
Unlock the rotor cover (bayonet lock to "lock open").
Remove the rotor cover with the quartz glass and, if applicable, the cleaning rotor.
– Turn the turning valve to the dirt water outlet to eliminate any vacuum that may have built
up in the container.
EN
FCL0022