Accessory Installation - Enerpac ZU4 T Serie Manual De Instrucciones

Ocultar thumbs Ver también para ZU4 T Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
Figure 8, Brush Cap Removal
A. Brush Cap

8.0 ACCESSORY INSTALLATION

The pressure transducer, heat exchanger, pressure switch,
pendant / foot switch, valve solenoids (A) and (B) are supplied
with connectors that plug into the proper plug-ins found on the
electrical power board (Figure 9).
For further information and instructions on accessories see the
following web links:
Pressure Transducer
http://www.wika.de/pdf/betriebsanleitungen/ba_m_1x.pdf
Flat ribbon
cable terminal
Oil-level switch
Temperature switch
Pressure switch
Filter
Pressure transducer
Heat exchanger fan
B. Brush Cap Latch
Line in
Motor leads
Figure 9, Electric Power Board Configuration
Float/Temp Switch
http://www.barksdale.com/products/level/PDF_level/Pg02_7.pdf
http://www.barksdale.com/products/templ/PDF_temp/ml1s.pdf
Heat Exchanger
http://nmbtc.com/ (in the menu bar slide the mouse over
"products" and watch a sub-menu to show up. Click on "cooling
solutions", click on "product catalog" in the list on the right-hand
side and again click on "dc fan". In the following dialogue-screen
enter 5920PL-05W-B40 into the Search-field and click "go".)
8.1 Pressure Transducer Replacement
All ZU4 Torque Wrench pumps come with a pressure transducer
pre-installed. To replace a pressure transducer refer to the Service
Instructions for the pressure transducer.
Variable Rate Display
The pressure transducer is very accurate and measures pressure
real time. To aid the operator when pressure is changing rapidly,
Z-Class provides a variable rate display.
The micro processor will automatically change the increment value
based on rate of pressure change, increments are 50, 100, 500, and
1000 psi (4, 7, 35, and 70 Bar). When the rate of pressure change is
slow, the display will update in 50 psi (4 Bar) increments. When it
changes rapidly, the display will update in 1000 psi (70 Bar)
increments.
Replaceable fuse F1
Replaceable fuse F3
10
Pendant
Retract
Advance

Publicidad

Tabla de contenido
loading

Tabla de contenido