trigger. By turning the control screw clockwise, the stroke force increases and decreases to the left. Check
the set of stroke force and repeat the procedure until the recommended stroke force is set according to the
following table (does not apply for all types of rivet nuts):
Rivet nut
M4
M5
M6
M8
M10
M12
11) Put the rivet on the mandrel and push towards the anvil, this will screw on the rivet.
12) Put the screwed rivet into the prepared hole.
13) Press the trigger and the rivet will be riveted in.
14) Relieve the trigger, the mandrel will screw out from the rivet (if it is not fully screwed out, use the
unscrewing button).
15) Check the fastened rivet
- if the rivet is not fully fastened it is necessary to increase the stroke.
- if the rivet is too fastened, which results in deformation of the rivet and the mandrel is hard to unscrew
out from the rivet, it is necessary to decrease the stroke.
16) Check the setting-up of the anvil according to the step 8).
The tool, which is set up and prepared this way is ready for riveting.

3. TOOL MAINTENANCE

During maintenance the tool must be disconnected from the source of compressed air !!!

3.1 DAIly mAINTENANCE

Before starting work, apply several drops of lubricating oil (we recommend hydraulic oil HYSPIN AWHM 32
CASTROL or hydraulic oils grade HLP ISO VG 32) into the air inlet of the tool, on condition there is no lubricating
device connected in the air distribution.
Check the tool for air leakage, if necessary replace damaged hoses and clasps.
If the pressure regulator is not equipped with a filter, blow through the air hose before its connection to the
tool in order to get rid of impurities and water. If the pressure regulator has a filter, dry it out.
Check whether the fixed nose-piece corresponds to the BR diameter and that all screw threads and joints are
tightened properly. Check that the front nozzle is tightened properly into the hydraulic body of the tool.
Check whether the air outlets are really empty.

3.2. WEEkly mAINTENANCE

Cleaning of the tool and replacement of worn or non-functional parts and if necessary, refill the oil according
to the chapter 3.4.
Unscrew the anvil and mandrel according to the chapter 2.4., point 1) to 3) and clean them thoroughly. Visually
check - especially the mandrel, anvil and front nozzle - if worn or damaged, replace them. Dismounted parts
should be reinstalled according to the chapter 2.4., points 5) to 7), including setting up point 8).
Stroke force F
Al (aluminium)
3
5
7
11
13
15
( kN )
t
St (steel)
5
9
11
13
15
19
E N G L I S H
Rv (stainless steel)
7
9
11
13
15
21
7

Publicidad

Tabla de contenido
loading

Tabla de contenido