1 About This Documentation
Documentation validity
This documentation applies to EV03 series electropneumatic pressure regulators
and base plates. It is intended for installers, programmers, electrical engineers,
service personnel, and system owners and contains important information on the
safe and proper installation, commissioning, and operation of the product and how
to remedy simple malfunctions yourself.
Additional documentation
O Only commission the product once you have obtained the following
documentation and understood and complied with its contents.
– System documentation (provided by the machine/system manufacturer and
not included in the AVENTICS scope of delivery)
Presentation of information
To allow you to begin working with the product quickly and safely, uniform safety
instructions, symbols, terms, and abbreviations are used in this documentation.
For better understanding, these are explained in the following sections.
Safety instructions
In this documentation, there are safety instructions before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to avoid
these hazards must be followed. Safety instructions are set out as follows:
Hazard type and source
Consequences of non-observance
O Measures to avoid these hazards
W
Safety sign (warning triangle): draws attention to the risk
W
Signal word: identifies the degree of hazard
W
Hazard type and source: identifies the hazard type and source
W
Consequences: describes what occurs when the safety instructions are not
complied with
W
Precautions: states how the hazard can be avoided
Meaning of the signal words
Table 1:
Hazard classes according to ANSI Z 535.6-2006
Indicates a hazardous situation which, if not avoided, will certainly result in death
or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or
serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or
moderate injury.
Indicates that damage may be inflicted on the product or the environment.
Symbols
The following symbols indicate information that is not relevant for safety but that
helps in comprehending the documentation.
Table 2:
Meaning of the symbols
Symbol Meaning
If this information is disregarded, the product cannot be used or
operated optimally.
O
Individual, independent action
1.
Numbered steps:
2.
The numbers indicate sequential steps.
3.
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE
Abbreviations
This documentation uses the following abbreviations:
Table 3:
Abbreviations
Abbreviation
Meaning
I/O
Input/Output
ESD
Electrostatic discharge
EV03
Electropneumatic pressure regulator valve, nominal width 3
FE
Functional Earth
UA
Valve power supply
UL
Electronics power supply
DIAG
Diagnosis
2 Notes on Safety
About this chapter
The product has been manufactured according to the accepted rules of current
technology. Even so, there is risk of injury and damage to equipment if the following
chapter and safety instructions of this documentation are not followed.
O Read these instructions completely before working with the product.
O Keep this documentation in a location where it is accessible to all users at all
times.
O Always include the documentation when you pass the product on to third parties.
Intended use
The EV03 pressure regulator is a pneumatic device with integrated electronics that
is only designed to regulate pneumatic pressures. It may be operated only in the
installed state together with the base plate. Only use compressed air as the medium.
Operation with pure oxygen is not permitted.
The EV03 pressure regulator is intended for professional use only.
The EV03 pressure regulator may only be used for industrial applications.
An individual license must be obtained from the authorities or an inspection center
for systems that are to be used in a residential area (residential, business,
and commercial areas). In Germany, these individual licenses are issued by the
Regulating Agency for Telecommunications and Post (Regulierungsbehörde für
Telekommunikation und Post, Reg TP).
O The pressure regulator may only be used within the limits listed in the technical
data.
Improper use
Improper use of the product includes:
W
Using the EV03 for any application not stated in these instructions,
W
Using the EV03 under operating conditions that deviate from those described
in these instructions,
W
Using the EV03 as a safety component
W
Using the EV03 in safety-related controls,
W
Evaluating the display values for safety-relevant functions,
W
Using the EV03 as a pressure relief valve within the meaning of the ISO 4414
standard.
Neither the EV03 pressure regulators nor the base plates comply with the ISO 13849
standard.
O Contact AVENTICS GmbH if you would like to use the device in a safety control
sequence. The address is printed on the back cover of these instructions.
The user alone bears the risks of improper use of the product.
Personnel qualifications
The work described in this documentation requires basic electrical and pneumatic
knowledge, as well as knowledge of the appropriate technical terms. In order to
ensure safe use, these activities may therefore only be carried out by qualified
technical personnel or an instructed person under the direction and supervision
of qualified personnel.
Qualified personnel are those who can recognize possible hazards and institute
the appropriate safety measures, due to their professional training, knowledge,
and experience, as well as their understanding of the relevant regulations pertaining
to the work to be done. Qualified personnel must observe the rules relevant to the
subject area.