1 About this Documentation
Documentation validity
This documentation applies to AV 03-EP and AV05-EP series electropneumatic
pressure regulators and base plates. It is intended for installers, programmers,
electrical engineers, service personnel, and system owners and contains important
information on the safe and proper installation, commissioning, and operation
of the product and how to remedy simple malfunctions yourself.
The chapter 13 "AV-EP in ein AV-Ventilsystem integrieren" describes the
subsequent extension of AV-EP pressure regulators for fieldbus connection
in configured valve systems.
Additional documentation
O Only commission the product once you have obtained the following
documentation and understood and complied with its contents.
– R412015575, Safety instructions, HF, AV, LS
– R412018507, Valve system assembly and connection, AV03/AV05
(assembly instructions)
– System documentation (provided by the machine/system manufacturer
and not included in the AVENTICS scope of delivery)
If the valve system has a bus coupler:
– Bus coupler system description (only on CD)
You can also find all instructions, with the exception of the system
documentation, on the CD R412018133.
Presentation of information
To allow you to begin working with the product quickly and safely, uniform safety
instructions, symbols, terms, and abbreviations are used in this documentation.
For better understanding, these are explained in the following sections.
Notes on Safety
In this documentation, there are safety instructions before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to avoid
these hazards must be observed. Safety instructions are set out as follows:
Hazard type and source
Consequences of non-observance
O Measures to avoid these hazards
W
Safety sign: draws attention to the risk
W
Signal word: identifies the degree of hazard
W
Hazard type and source: identifies the hazard type and source
W
Consequences: describes what occurs when the safety instructions
are not complied with
W
Precautions: states how the hazard can be avoided
Meaning of the signal words
Table 1:
Hazard classes according to ANSI Z 535.6-2006
Indicates a hazardous situation which, if not avoided, will certainly result in death
or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
Indicates that damage may be inflicted on the product or the environment.
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE
Symbols
The following symbols indicate information that is not relevant for safety but that
helps in comprehending the documentation.
Table 2:
Meaning of the symbols
Symbol Meaning
If this information is disregarded, the product cannot be used
or operated optimally.
O
Individual, independent action
1.
Numbered steps:
2.
The numbers indicate sequential steps.
3.
Abbreviations
This documentation uses the following abbreviations:
Table 3:
Abbreviations
Abbreviation
Meaning
AES
Advanced Electronic System
AV
Advanced Valve
AV-EP
AV03-EP or AV05-EP series electropneumatic pressure regulator
I/O module
Input/Output module
ESD
Electrostatic discharge
FE
Functional Earth
PLC
Programmable Logic Controller, or PC that takes
on control functions
UA
Valve power supply
UL
Electronics power supply
DIAG
Diagnosis
2 Notes on Safety
About this chapter
The product has been manufactured according to the accepted rules of current
technology. Even so, there is risk of injury and damage to equipment if the following
chapter and safety instructions of this documentation are not followed.
O Read these instructions completely before working with the product.
O Keep this documentation in a location where it is accessible to all users
at all times.
O Always include the documentation when you pass the product on to third parties.
Intended use
The AV-EP pressure regulator is a pneumatic device with integrated electronics
that is only designed to regulate pneumatic pressures. It may be operated only
in the installed state together with the base plate in an AV valve system. Only use
compressed air as the medium. Operation with pure oxygen is not permitted.
The AV-EP pressure regulator is intended for professional use only.
The AV-EP pressure regulator may only be used for industrial applications.
An individual license must be obtained from the authorities or an inspection center
for systems that are to be used in a residential area (residential, business, and
commercial areas). In Germany, these individual licenses are issued by the
Regulating Agency for Telecommunications and Post (Regulierungsbehörde
für Telekommunikation und Post, RegTP).
O The pressure regulator may only be used within the limits listed in the
technical data.
Improper use
Improper use of the product includes:
W
Using the AV-EP for any application not stated in these instructions,
W
Using the AV-EP under operating conditions that deviate from those described
in these instructions,
W
Using the AV-EP as a safety component,
W
Using the AV-EP in safety-related controls,
W
Evaluating the display values for safety-relevant functions,
W
Using the AV-EP as a pressure relief valve within the meaning of the
ISO 4414 standard.
Neither the AV-EP pressure regulators nor the AV-EP base plates comply with
the ISO 13849 standard.
O Contact AVENTICS GmbH if you would like to use the device in a safety control
sequence. The address is printed on the back cover of these instructions.
The user alone bears the risks of improper use of the product.
16