AVENTICS | PE2 | R412006964–BAL–001–AE | English
1

About This Documentation

This documentation is valid for PE2 series pressure switches.
This documentation is intended for installers, operators, and service technicians.
O
Only commission the product once you have obtained the system documentation and
understood and complied with its contents.
Presentation of information
Safety instructions
Indicates a hazardous situation which, if not avoided, could result in minor or moderate
injuries.
Indicates that damage may be inflicted on the product or the environment.
Symbols
Operation may be impaired if this information is disregarded.
2
Notes on Safety
The product has been manufactured according to the accepted rules of current technology.
Even so, there is risk of injury and damage to equipment if the following chapter and safety
instructions of this documentation are not followed.
O
Read these instructions completely before working with the product.
O
Keep this documentation in a location where it is accessible to all users at all times.
O
Always include the documentation when you pass the product on to third parties.
Intended use
The PE2 pressure switch is a pneumatic device for the monitoring of pressure values. It is
intended for application in a machine or system. It may be operated only in the installed state.
O
Observe the performance limits listed in the technical data.
The product is intended for professional use only.
Improper use includes applying aggressive or flammable gases or liquids to the PE2 pressure
switch.
AVENTICS GmbH is not liable for any damages resulting from improper use. The user alone
bears the risks of improper use of the product.
Personnel qualifications
The work described in this documentation requires basic mechanical, electrical, and pneumatic
knowledge, as well as knowledge of the appropriate technical terms. In order to ensure safe use,
these activities may therefore only be carried out by qualified technical personnel or an
instructed person under the direction and supervision of qualified personnel.
Qualified personnel are those who can recognize possible hazards and institute the appropriate
safety measures, due to their professional training, knowledge, and experience, as well as their
understanding of the relevant regulations pertaining to the work to be done. Qualified personnel
must observe the rules relevant to the subject area.
General safety instructions
W
Observe the regulations for accident prevention and environmental protection.
W
Observe the safety instructions and regulations of the country in which the product is used
or operated.
W
Only use AVENTICS products that are in perfect working order.
W
Follow all the instructions on the product.
W
Only use accessories and spare parts approved by the manufacturer.
W
Comply with the technical data and ambient conditions listed in the product documentation.
W
Never modify the product on your own authority.
W
You may only commission the product if you have determined that the end product (such as
a machine or system) in which the AVENTICS products are installed meets the country-
specific provisions, safety regulations, and standards for the specific application.
Safety instructions related to the product and technology
Improperly installed compressed air lines!
Danger of injury!
O
Lay the compressed air lines so that no one can trip over them.
Dangerous system operating states if the PE2 pressure switch is disconnected from the
voltage source during operation!
Danger of injury and system damage from uncontrolled system operating states.
O
Do not disconnect the PE2 pressure switch from the voltage source during operation!
CAUTION
NOTICE
CAUTION
General instructions on equipment and product damage
Mechanical loads!
Damage to the device!
O
Make sure that you never expose the device to mechanical loads or mount it with
mechanical stress.
O
Avoid mechanical stress when connecting the pneumatic tubing and the electrical
connection.
O
Make sure that the device is not damaged by falling parts or incorrect tool usage.
3

Delivery Contents

The delivery contents include:
W
1 PE2 electronic pressure switch
W
1 set of operating instructions for the PE2
W
2 mounting screws for devices with flange connection
4

Device Description

The PE2 pressure switch is used as a switch in signaling, control, and regulation circuits.
It monitors the applied relative pressure and converts it, depending on the PE2 version, into a
digital switch signal, into two digital switch signals, or into a digital and/or analog current signal.
The switching behavior is presented in Figs.
Device overview
PE2 with plate connection
1
1
Electrical connection, M12 x 1, 5-pin,
A-coded
2
Display
PE2 with internal thread
2
1
Electrical connection, M12 x 1, 5-pin,
A-coded
2
Display
Description of the displays
Example views based on a 2P version with a measurement range of 0–16 bar and configured
switching function 1 as HNC and switching function 2 as FNO (see Fig.
1A Configuration of output 1 or plain text
1B Configuration of output 2
5
Assembly
System is operating under voltage and pressure!
Working on the system when under electrical voltage and pressure could lead to injuries and
damage the PE2.
O
Make sure the relevant system component is not under pressure or voltage before
assembling or disassembling the PE2.
O
Before assembly, exhaust the relevant system components.
O
Assembly work may only be carried out by trained professionals.
O
Pay particular attention to the valid and relevant local safety regulations.
Connecting the pneumatics
O
Comply with the limits for pressure and temperature (see "10 Technical Data").
1. Make sure that the system is not under voltage or pressure.
2. Connect the pressure switch with the pressure system:
– Flange connection M5: MA = 2.5+0.5 Nm
– Connection G1/4, MA = 12+1 Nm
Electrical connection
Use pre-assembled plug connections and cables to connect the modules.
O
Observe the pin assignments (see Fig.
and cables.
To electrically connect the PE2:
O
Attach the M12x1 connector on the connecting cable to the device plug.
O
Observe the relevant DIN/VDE regulations, as well as country-specific regulations.
Operation without sufficient grounding is not permissible.
NOTICE
3
to
5
.
3
Control panel with three buttons
4
Pneumatic plate connection
3
Control panel with three buttons
4
Through holes
5
Thread connection G 1/4
6
).
2
Pressure unit
3
Pressure value, menu item, value,
or selection
CAUTION
1
2
8
), if you do not use pre-assembled plug connections
5

Publicidad

Tabla de contenido
loading

Tabla de contenido