Measurement
Exit the soft foot
Fig. 31 Soft foot check result screen
If the deviation is less than 0.05 mm (2 mils), the foot has a good support.
Check all feet, the one with the largest deviation is the soft foot.
It is normally worthwhile to try to improve the support of the soft foot by adding shims.
Add the amount of shims corresponding to the largest deviation measured.
Check again all feet following the same procedure.
Ater checking all feet, navigate to the Measurement icon and confirm with OK, to measure
the alignment
Select Exit icon to exit the soft foot module, and return to the previous screen.