Setting the Parameters for Welding Data Recording
• In the function display (33), rotate the "e-Drive"
• Press "e-Drive"
• Select "Welding Data Record." in the "Setup" menu by rotating the "e-Drive"
Switching on data recording:
• Rotate the "e-Drive"
Rotate the "e-Drive"
Switching on the name affix for the welding seam (optionally, as required):
• Rotate the "e-Drive"
Rotate the "e-Drive"
Setting the welding seam name (optionally, as required):
• Rotate the "e-Drive"
The current name is displayed on the top line. "--" means that a name has not been defined.
Rotate the "e-Drive"
Enter the desired name (see Chap. "Entering Names or Passwords"), confirming this afterwards by selecting the
symbol
and by pressing the "e-Drive"
Setting the name of the rolls (optionally, as required):
• See Setting the welding seam name for the setting procedure.
Setting the threshold value for recording:
• Rotate the "e-Drive"
Rotate the "e-Drive"
Switching off alarm value monitoring (optionally, as required):
• See Switching on data recording for the setting procedure.
Important: When the alarm is switched off, then exceeded alarm values will also not be recorded.
Switching off the acoustic alarm (optionally, as required):
• See Switching on data recording for the setting procedure.
Setting the minimum temperature alarm:
• See Setting the threshold value for recording for the setting procedure.
24
briefly.
to select "Data Recording" and press "e-Drive"
to select "I" and press "e-Drive"
to select "Seam Naming" and press "e-Drive"
to select "I" and press "e-Drive"
to select "Set Seam Name" and press "e-Drive"
to select "Edit Seam Name" and press "e-Drive"
to select "Init. Value Record." and press "e-Drive"
to set the value and press "e-Drive"
to select the Settings menu
briefly.
briefly.
.
briefly.
.
and pressing it briefly.
briefly.
briefly.
briefly.
briefly.
briefly.