Plumbing Connections; Plumbing Accessories (Optional); Condensate Outlet/Collection; Gas Supply - Sime Brava Slim HE 25 T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Brava Slim HE 25 T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
m
CAUTION
– The height of the boiler is to be such that disassembly
and maintenance interventions are facilitated.
2.9

Plumbing connections

The plumbing connections have the following characteristics
and dimensions.
48
Sc
=
65 65 65 65
=
M
Mb G
Rb
R
400
Description
M - System delivery
R - System return
Mb - Hot water tank delivery
Rb - Hot water tank return
G - Gas supply
Sc - Condensate outlet
All manuals and user guides at all-guides.com
2.9.1
To facilitate plumbing and gas connections to the systems, the
accessories as shown in the table below are available and are to
be ordered separately from the boiler.
DESCRIPTION
Installation plate
Cocks kit
Wall mount replacement kit for other makers
Fitting protection Kit
Polyphosphate dosing kit
Dosing recharge kit
NB:
to be found on the packaging.
2.10
In order to collect the condensate, it is recommended that:
– the appliance condensate outlets and the smoke outlet are
– a neutralising device is prearranged
– the outlet incline is >3% .
m
Sc
95
175
2.11
Brava Slim HE 25 T
G20 and can also work with G31 without the need for any type
of mechanical conversion. Simply select parameter "03" (see "
Parameter setting and display") and set the type of gas to be
Fig. 13
used.
If changing the type of gas to be used, carry out the entire
appliance "COMMISSIONING" phase.
Brava Slim HE 25 T
Boiler connection to the gas mains must be carried out in full
Ø 3/4" G
compliance with installation Standards in force.
Ø 3/4" G
Before connecting the boiler to the gas mains, the user must
Ø 3/4" G
ensure that:
Ø 3/4" G
– the type of gas is correct for the appliance
Ø 3/4" G
– the pipes are clean
Ø 20 mm
– the gas supply pipe is the same dimension as or greater than
a
m

Plumbing accessories (optional)

kit instructions are supplied with the accessory itself or are

Condensate outlet/collection

ducted
CAUTION
– The condensate outlet duct must be airtight,
suitably sized to that of the siphon and must not be
restricted at any point.
– The condensate outlet must be constructed in full
compliance of the National or Local regulations in
force.
– Before commissioning the appliance, fill the siphon
with water.

Gas supply

boilers leave the factory prearranged for gas
that of the boiler fitting (G3/4") and with a load loss less than
or equal to that contemplated between the gas mains and the
boiler.
DANGER
Once installation has been completed, check that
the joints are air tight as indicated in the installation
Standards.
CAUTION
It is recommended that the gas line has a suitable
filter.
CODE
8075441
8091820
8093900
8094530
8101700
8101710
69